How to use less gas.
Most homes burn more gas than they need to — not because the boiler is bad, but because the system around it was never set up properly. Here's what actually moves the bill, in plain English: some of it is free and you can do it today, some of it is the sizing and setup work I do for a living.
Free changes first → WhatsApp MarkFree changes you can make today
No parts, no engineer, just settings
- Turn the heating flow temperature down. Most boilers leave the factory at 70–80°C. If you have a combi and radiators only, turn the radiator/flow dial down to around 55–60°C. The boiler starts condensing properly and typically uses 6–10% less gas — the radiators run warm for longer instead of hot in bursts, and the house is just as comfortable.
- Switch off combi preheat. The "preheat" or "eco off" function keeps water hot inside the boiler all day for a slightly faster tap. It quietly burns gas around the clock — turn it off.
- Drop the room thermostat 1°C. Worth roughly 10% on its own. Try 19–20°C instead of 21.
- Use the TRVs. Radiator valves aren't on/off switches — set spare rooms and bedrooms to 2–3 and let them sit cooler than the living space.
- Heat on a schedule, not all day. A well-set timer beats "leave it on low" in almost every home.
- Bleed radiators and keep them clear. Air at the top and a sofa in front both mean the boiler works harder for the same warmth.
One caution: if you have a hot water cylinder, don't turn the cylinder side down — stored hot water must be kept at 60°C to stay safe. That's the one to ask me about.
Why boiler settings work: condensing, explained
A modern boiler is called a condensing boiler because it can claw heat back out of its own flue gases — but only when the water returning to it is cool enough, roughly below 55°C. Run the system hot and that recovery never happens: you've got a 94%-efficient boiler running at 80-something percent, every hour, for years.
Everything on this page is really one idea wearing different hats: set the system up so the boiler can run as cool as possible while still keeping every room warm. Flow temperature is the free version of it. Radiator sizing, pipe sizing, balancing and weather compensation are the engineered versions of it.
Correctly sized radiators — the key to running cool
A radiator's output collapses as the water cools: at 55°C flow, a radiator puts out roughly half what it does at 75°C. So whether you can run cool comes down to whether your radiators were sized for it. When I size radiators I work from the room's actual heat loss — its size, windows, walls, insulation — and pick radiators generous enough to hold the room at low flow temperatures. One undersized radiator in a bathroom can force the whole system to run hot for the sake of one room; putting the right radiator in that one room lets the entire house run efficient.
| Flow temperature | Radiator output (vs 75°C) | Boiler condensing? |
|---|---|---|
| 75–80°C (factory setting) | 100% | Barely — most heat lost up the flue |
| 65°C | ~75% | Partly |
| 55–60°C | ~55–65% | Yes — the efficient zone |
| 45°C (well-sized rads / UFH) | ~40% | Fully — maximum efficiency |
Pipe sizing — the part nobody sees
Pipework is the system's road network. Undersized or badly routed pipes starve the furthest radiators, force the pump to work flat out, cause rushing noises, and make the system impossible to balance — so someone turns the boiler up to compensate, and the bill climbs. When I design or extend a system I size each pipe run for the flow it actually carries, so every radiator gets its share without the boiler shouting to be heard at the back of the house.
Balancing — the forgotten free-ish win
Even a well-piped system needs balancing: adjusting the lockshield valve on every radiator so each takes just its share of hot water. Unbalanced systems overheat rooms near the boiler and never warm the far end of the house. It's careful, unglamorous work with thermometers and patience — and it's included when I install or overhaul a system.
Smart controls and zoning — heat only what you're using
Modulating controls, not on/off
A basic thermostat slams the boiler on at full power and off again, over and over. A modulating smart control (OpenTherm or the manufacturer's own version) talks to the boiler continuously — "give me 6kW, now 4, now 2" — so it simmers instead of boiling and stays in its efficient range. Same house, same warmth, less gas.
Weather compensation
A small outdoor sensor tells the boiler how cold it actually is outside, and the boiler picks the lowest flow temperature that will hold the house at your set point — automatically, all year. It's the "run as cool as possible" idea made permanent, and on a well-sized system it's the single best efficiency control you can fit.
Zoning — where the big-house savings live
In a larger home, heating everywhere because one room is cold is like lighting every room in the house because you're reading in one of them. Proper zoning gives bedrooms, living areas and lesser-used wings their own thermostats and timetables — bedrooms warm for evening and morning, living rooms for daytime, guest rooms only when there are guests. Combined with modulation and weather compensation, well-designed controls typically cut 10–20% off a gas bill compared with one on/off stat in the hall — and in a big zoned house, often more. More on how I design large systems here.
Want your system set up to run cheap?
I can check your flow temperatures, balance the system, size any problem radiators properly and fit modulating smart controls with weather compensation — on your current boiler or with a new one.
WhatsApp Mark — preferred Call 07717 884680Thinking of a new boiler anyway? Get a fixed price in 60 seconds — smart controls can be added to any quote.